Demands, storage and distribution

Design starts from average-day demand — population times per-capita use — scaled by peaking factors: maximum-day demand commonly runs about 1.5–2 times the average, and peak-hour higher again. Storage has three components that must not be conflated: equalising storage for diurnal swings, fire storage (fire flow times its duration), and emergency storage. Distribution pressure must stay high enough at the tap and low enough to protect pipes, which is why systems are split into pressure zones set by ground elevation.

Average demand = population × per-capita use  ·  Fire storage = fire flow × duration

Worked example Maximum-day demand and fire storage

Given: A town of 50,000 people uses 100 gal/capita/day on average. The maximum-day factor is 1.8, and the required fire flow is 3,000 gal/min for 3 hours. Find the maximum-day demand and the fire storage.

Solution:

  1. Average demand: 50,000 × 100 = 5,000,000 gal/day = 5.0 MGD.
  2. Maximum-day demand: 5.0 × 1.8 = 9.0 MGD.
  3. Fire storage: 3,000 × 60 × 3 = 540,000 gal.

Answer: Maximum-day demand = 9.0 MGD; fire storage = 540,000 gal.

The treatment train: coagulation to filtration

Conventional treatment destabilises colloids with a coagulant in a rapid mix, grows floc in a slow flocculator, settles it in a sedimentation basin sized by surface overflow rate, and polishes the water through a filter sized by filtration rate (flow per unit filter area). Each stage is checked by its own loading: overflow rate for the basin, filtration rate for the filter, detention and velocity gradient for the mixers. The train is only as strong as its weakest loading check.

Filtration rate = Q / filter area  ·  Basin check: SOR = Q/A

Worked example Filtration rate

Given: A filter 20 ft by 30 ft treats 2.0 MGD. Find the filtration rate in gal/min/ft².

Solution:

  1. Area = 20 × 30 = 600 ft².
  2. Rate = 2,000,000 gal/day / 600 ft² = 3,333 gal/day/ft².
  3. Convert: 3,333 / 1,440 = 2.31 gal/min/ft².

Answer: Filtration rate ≈ 2.31 gpm/ft².

Disinfection and the CT concept

Disinfection credit is earned as CT: the disinfectant residual C (mg/L) multiplied by the effective contact time T10 (minutes) — the time by which 10% of the water has passed through the contactor, found from the theoretical detention time times a baffling factor. Required CT rises as temperature falls and pH rises (for chlorine), and the target organism sets the log inactivation to be met. Using the full theoretical detention time instead of T10 overstates the credit — the standard trap.

CT = C × T10  ·  T10 = baffling factor × (V/Q)

Worked example CT with a baffling factor

Given: A clearwell gives a theoretical detention time of 60 min with a baffling factor of 0.7. The chlorine residual is 0.5 mg/L. Find the CT achieved.

Solution:

  1. T10 = 0.7 × 60 = 42 min.
  2. CT = 0.5 × 42 = 21 mg·min/L.

Answer: CT = 21 mg·min/L.

3-question mini-quiz

Drinking Water Distribution and Treatment

Choose your answer, then check it to see the result and explanation.

1. A clearwell holds 100,000 gal at a flow of 1.0 MGD with a baffling factor of 0.5. T10 is:

2. If the chlorine residual doubles and T10 is unchanged, the CT:

3. Equalising storage in a distribution system exists to:

Ready for the complete rehearsal?

Step up from this three-question taster to the full timed PE WRE simulation — 80 questions in exam conditions, with a per-area diagnostic.

Keep building exam speed

This whole hub is free — every area page, mini-quiz and podcast. When you are ready to rehearse under exam conditions, the separate PE WRE exam simulation runs the full 80 questions against the clock.

Preview the PE WRE exam simulation Open the exam simulator