Parameters and BOD kinetics
The working parameters are BOD, COD, dissolved oxygen, suspended and dissolved solids, nutrients (nitrogen and phosphorus), pH, alkalinity and hardness. BOD follows first-order decay: the BOD remaining at time t is Lt = L0e−kt, and the BOD exerted — the standard BOD5 — is L0(1 − e−5k). The rate constant corrects with temperature, and confusing BOD remaining with BOD exerted is the standing trap of this area.
Lt = L0 e−kt · BOD5 = L0(1 − e−5k)
Worked example Ultimate BOD from a BOD5 result
Given: A sample has BOD5 = 150 mg/L with k = 0.23/day. Find the ultimate BOD, L0.
Solution:
- Exerted fraction in 5 days: 1 − e−(0.23 × 5) = 1 − e−1.15 = 1 − 0.317 = 0.683.
- L0 = 150 / 0.683 = 220 mg/L.
Answer: Ultimate BOD ≈ 220 mg/L.
The dissolved-oxygen sag
Below a discharge, deoxygenation from BOD decay and reaeration from the surface compete, and the dissolved-oxygen deficit traces the Streeter–Phelps sag curve to a critical point — the lowest DO, furthest downstream — before recovering. Saturation DO falls as temperature rises (about 9.2 mg/L at 20 °C in fresh water), so the same load is more dangerous in warm water. Exam questions ask for the deficit or DO at a time, the critical-point idea, or the remaining BOD that drives it.
DO = DOsat − deficit · BOD remaining drives deoxygenation at rate kdL
Worked example BOD remaining downstream
Given: A discharge leaves L0 = 20 mg/L of BOD in a stream with k = 0.23/day. Find the BOD remaining after 3 days of travel.
Solution:
- L3 = 20 × e−0.23 × 3 = 20 × e−0.69.
- e−0.69 = 0.502, so L3 = 20 × 0.502 = 10.0 mg/L.
Answer: BOD remaining ≈ 10.0 mg/L after 3 days.
Eutrophication, standards and groundwater quality
Eutrophication is nutrient-driven algal growth followed by oxygen-consuming decay; phosphorus usually limits fresh waters and nitrogen coastal waters, so control targets the limiting nutrient. Surface-water standards are set by designated use, with criteria for DO, pH, temperature and toxics, administered in the United States through discharge permits. Groundwater quality moves slowly and persists: plumes follow the gradient at the seepage velocity, sorption retards contaminants relative to the water, and hardness and alkalinity are reported as CaCO3 equivalents.
Hardness as CaCO3 = ion (mg/L) × 50 / equivalent weight of the ion
Worked example Hardness as CaCO3
Given: A water contains Ca²⁺ = 40 mg/L (equivalent weight 20) and Mg²⁺ = 12.15 mg/L (equivalent weight 12.15). Find the total hardness as CaCO3.
Solution:
- Calcium hardness: 40 × 50/20 = 100 mg/L as CaCO3.
- Magnesium hardness: 12.15 × 50/12.15 = 50 mg/L as CaCO3.
- Total: 100 + 50 = 150 mg/L as CaCO3 — a hard water.
Answer: Total hardness = 150 mg/L as CaCO3.