PE WRE Learning Hub · PE Civil: Water Resources and Environmental · Area 8 of 12
Groundwater and Wells — PE WRE
Topic video on its way — a detailed walkthrough of Groundwater and Wells, with animations and worked examples.
Watch the topic: the detailed video walkthrough of Groundwater and Wells will sit here.
Take the 3-question mini-quiz ↓
Aquifers and Darcy's law
An aquifer stores and transmits water; a confined aquifer is sandwiched between low-permeability layers and its water is under pressure, while an unconfined aquifer has the water table as its upper boundary. Darcy's law gives the discharge Q = KiA, where K is hydraulic conductivity and i the hydraulic gradient. The Darcy velocity, Q/A, is a flux, not a particle speed: the seepage velocity is Ki/n, faster by the porosity. Transmissivity T = Kb packages conductivity and thickness for well formulas.
Q = K i A · Seepage velocity vs = K i / n · T = K b
Worked example Darcy flow and seepage velocity
Given: An aquifer has K = 10 ft/day and porosity n = 0.25. The gradient is 0.01 and the flow section is 100 ft². Find Q and the seepage velocity.
Solution:
- Q = 10 × 0.01 × 100 = 10 ft³/day.
- Darcy velocity = Q/A = 0.10 ft/day; seepage velocity = 0.10/0.25 = 0.40 ft/day.
Answer: Q = 10 ft³/day; seepage velocity = 0.40 ft/day.
Wells and drawdown analysis
Pumping lowers heads in a cone of depression. At steady state in a confined aquifer the Thiem equation relates drawdown between two observation points to transmissivity: s = [Q/(2πT)] ln(r2/r1), in US field units s (ft) = (264 Q/T) log10(r2/r1) with Q in gal/min and T in gal/day/ft. The Theis equation adds time for transient conditions. Specific capacity, Q/s at the well, is the quick health check of a well's performance, and interfering wells add their drawdowns by superposition.
Thiem (US): s = (264 Q / T) · log10(r2/r1) · Specific capacity = Q/s
Worked example Drawdown between observation wells
Given: A well pumps 500 gal/min from a confined aquifer with T = 10,000 gal/day/ft. Find the drawdown difference between observation wells at radii whose ratio r2/r1 = 10.
Solution:
- log10(10) = 1.0.
- s = (264 × 500 / 10,000) × 1.0 = 13.2 ft.
Answer: Drawdown difference = 13.2 ft across that tenfold radius interval.
Dewatering
Construction dewatering lowers the water table with wellpoints or deep wells so excavations stay dry and stable. The design flow comes from the same well equations — for an unconfined aquifer the Dupuit equation, Q = πK(H² − h²)/ln(R/r), with H the initial saturated thickness, h the pumped thickness at the well, and R the radius of influence. Underestimating K or the radius of influence underestimates the pumping plant; the exam tests the equation and the concept that drawdown, not the excavation depth alone, sets the duty.
Dupuit (unconfined): Q = πK(H² − h²) / ln(R/rw)
Worked example Dewatering flow from the Dupuit equation
Given: An unconfined aquifer has K = 20 ft/day, initial saturated thickness H = 30 ft, pumped thickness at the well h = 20 ft, radius of influence R = 300 ft and well radius rw = 1 ft. Find Q.
Solution:
- H² − h² = 900 − 400 = 500 ft².
- Numerator: π × 20 × 500 = 31,416.
- Denominator: ln(300/1) = 5.70.
- Q = 31,416 / 5.70 = 5,508 ft³/day ≈ 41,200 gal/day.
Answer: Dewatering flow ≈ 5,510 ft³/day (about 41,200 gal/day).